12V 12.5 Amp 105 Watts Switching Power Supply 5.00012

12V 12.5 Amp 105 Watts Switching Power Supply 5.00012

12V 12.5 Amp 105 Watts Switching Power Supply

• AC Input Range Selectable By Switch
• Protections: Short Circuit / Overload / Over Voltage
• Cooling By Free Air Convection
• Led Indicator for Power On
• 100% Full Load Burn-In Test
• High Efficiency, Long Life And High Reliability

 

MODEL Item Number 5.00012
Output DC VOLTAGE 12V
RATED CURRENT 12.5A  
CURRENT RANGE 0- 30A 0-26A 0- 20A 0-16.7A 0-12.5A 0-10A 0- 6.5A 0- 3.3A
RATED Power 99W 130W 150W 150W 150W 150W 156W 158.4W
RIPPLE &Amp; NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 120mVp-p 120mVp-p 200m Vp-p
VOLTAGE ADJ. RANGE 3.2 - 3.5V 4.75 - 5.5V 7.13 - 8.3V 8.55 - 9.9V 11.4 -13.5V 14.25 -16.5V 22.8 - 27.6V 45.6 - 52.8V
VOLTAGE TOLERANCE Note.3 ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION Note.5 ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME Note.7 800ms, 20ms/230VAC               1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 24ms/230VAC         20ms/115VAC at full load
INPUT VOLTAGE RANGE 90 - 132VAC I 180 - 264VAC selected by switch 254 - 373VDC
FREQUENCY RANGE 47 - 63Hz
EFFICIENCY (Typ.)
73%
78%
80%
83%
83%
83%
86%
86%
AC CURRENT (Typ.) 3A/115VAC                2A/230VAC
INRUSH CURRENT (Typ.) COLD START 45A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTION OVERLOAD 110 - 150% rated Output Power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
3.8 - 4.65V
5.75 - 6.75V
8.6 -10.1V
10.4 -12.2V
13.8 -16.2V
17.25 - 20.25~
27.6 - 32.4V
55.2 - 62.4V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT WORKING TEMP. -20 - +60°C (Refer to Output load derating curve)
WORKING HUMIDITY 20 - 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 - +85°C, 10 - 95% RH
TEMP. COEFFICIENT ±0.03%tC (0 - 50°C)
VIBRATION 10 - 500Hz, 2G 1Omin./1 cycle, period for 60min. each along X, Y, Zaxes
SAFETY &Amp; EMC (Note 6) SAFETY STANDARDS UL60950-1, TUV EN60950-1 ,GB4943 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 70% RH
EMI CONDUCTION &Amp;RADIATION Compliance to EN55022 (CISPR22) Class B,GB9254 CLASS B
HARMONIC CURRENT Compliance to EN61 000-3-2,-3,GB17625.1
EMS IMMUNITY Compliance to EN61 000-4-2,3,4, 5, 6, 8,11, ENV50204, EN55024, EN61 000-6-1, heavy industry level, criteria A
OTHERS MTBF 433.3Khrs min. MIL-HDBK-217F (25°C)
DIMENSION 199*98*38mm (L*W*H)
PACKING 0.7Kg; 20pcs/15Kg/O.72CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple &Amp; noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf &Amp; 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to High line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The Power Supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the Power Supply very quickly may lead to increase of the set up time.

Write a review

Please login or register to review
0 Product(s) Sold

Tags: 12v 125 amp 105 watts switching power supply 500012, 500012, transformers accessories 12.5, 5.00012, supplies